Description
The timer has the following connections and controls:
- PDT relay to activate the external device (C, No, Nc).
- Potentiometers to adjust the activation time: Minute adjusted potentiometer (P1) and Second adjusted potentiometer (P2).
- Timed Activation Button Connection (S,-): activates the timer relay during the programmed time.
- Button connection for Reset (R,-); Allows the timer to be deactivated before the programmed time has elapsed.
- Direct Activation Button Connection (Ab ,-): activates the timer relay when the button connected here is pressed.
- Connection for call activation (I1, I2): allows the calling wire and the negative from the outdoor panel be connected (4+N systems) and activate the time when making a call.
Technical specifications
- Power: 9~14 Vac;11~18 Vdc
- Consumption:
- With 12 Vdc power supply: 20 mA idle, 50 mA active.
- With 12 Vac power supply: 50 mA idle, 110 mA active.
- Maximum output values:
- Power (resistive load): 1250VA or 150W
- Voltage (resistive load): 125 Vdc, 380 Vac.
- Maximum temperature: 0~+65ºC
- Timing:
- P1: from 0 to 6 minutes approximately.
- P2: from 1 to 60 seconds approximately.
- Activation by call:
- Electronic call: 4Vpp~18Vpp.
- Alternate call: 4Vac~12Vac.
Technology: GENERICA
Weight: 0.073 kg
Measures of the packed product: 9x6,5x2,5 cm
EAN 13: 8424299290010